Interlock System
The interlock system is used in laboratory environments, drug production centers, and isolated rooms to increase productivity and meet defined standards.
There are environments in health and pharmaceutical complexes that are completely different in terms of temperature, pressure, and pollution.
in order to separate these environments, a corridor is created which is separated by doors. It is necessary to open door 1 and enter this corridor, to close the door or other doors, and vice versa.
So this is important by Magnetic sensors Installed on the doors, the appropriate diagnosis and command is sent to the interlock system controller.
Interlock system after analyzing the conditions, the appropriate command for the direction Electrical Lock, drop lock or Magnetic Lock Exports installed on doors.
Each door has an entrance and an exit that can be equipped with a traffic control system or exit key. This depends on the sensitivity of the collection and the user request.
In this environment, to interlock two doors, for each door, one output command for electric lock and 3 input commands for direction. exit button, Magnetic sensor, and Access Control System there is.
All installed equipment sends its commands to the interlock system so that after analyzing the conditions by the interlock system, a suitable output is issued.
This is the simplest model of an interlock system that can be generalized according to the user’s needs.
for example :
- Display with an allowed and unauthorized crossing display.
- The door is open, the system alarm is activated more than the specified time.
Finally, any other practical request can be implemented and executed by the employer.
Interlock system features
- Ability to create a network and increase the number of doors to 256 doors
- Has two modes of operation DOOR and Safe box with the ability to adjust on the board
- Has modular settings using seven segments and microswitches
- Test the inputs and outputs using LEDs built into the board
- Has voltage output for all types of electric lock, Drop bolt lock, and magnetic look
- Has a performance bezel on the board with the ability to enable and disable the system menu
- Ability to adjust the time for each relay separately from 0.1 to 99 seconds in DOOR mode
- Ability to set the time to close the door after opening, from 0.1 to 99 seconds
- Ability to set the time to open the door after sending the signal, from 0.1 to 99 seconds
- Ability to adjust the opening time of the second door after closing the first door and vice versa, from 0.1 to 99 seconds
- Display all details of system performance including input, output, and all errors on the board
Management Room And Office Door Control System
According to the needs of dear customers regarding the control of the management room and the creation of a comprehensive security pack that can be combined with access control systems (card reader, fingerprint And…) and has, among other things, the ability to manage from within the room to be able to control the system (active or inactive), caused us to design and produce a door control system for the management room and office.
Therefore, with complete research in this field, the door control system of the management room and office was designed, produced, and operated by the technical unit of Arman Company.
System description
In this system, two types of remotes are used with the ability of the manager and the secretary.
The administrator/physician remote is defined by the ability to unlock the system and summon a secretary for the system. The secretary remote only has the ability to open the door.
The manager/ physician can deactivate the system while resting by pressing the Lock key on their remote.
In this case, the red light above the door is on and the secretary remote is deactivated.
In case of need, by pressing the summons key by the manager or doctor, the system buzzer is activated and notifies the secretary.
Capabilities of the door control system of management room and office
- Ability to open the door by the manager and secretary using the remote control
- Ability to summon the secretary by the manager using the remote control and internal beaker
- Ability to work in two-timing modes and memory (latch) for different uses
- Ability to work with a variety of Built-in electric locks, Drop Bolt (Shaft), and magnetic lock
- Ability to work with Magnet Sensor (To make the door smarter) in two modes, AC and DAC
- Ability to combine with card reader system, M200, and M300 controller and fingerprint system
- Has a status light output (green and red) to display active and inactive system
- Ability to adjust the door opening time (lock) by the user using a potentiometer from 1 to 30 seconds
- Ability to adjust the time to activate the magnetic sensor, the door does not close from 1 to 240 seconds
- Has a direct output of 12 volts 300 mA for the traffic control system independently
- Has an internal power supply, 700 mA, amplified with capacitors for all types of built-in electric locks
- Has two types of outputs: relay as NC-NO command, system voltage 12 volts direct NC – NO
- Ability to disable Electrical Lock and Access Control System by the administrator using the remote control
- Ability to make the door smart, activate the alarm continuously and intermittently in case of unauthorized entry
- Ability to adapt to a variety of remote controls available in the market to the user’s order with frequencies 433 or 315
- Has input Magnet Sensor، exit button, video door phone, and any type of command as a short circuit